Please download Java(tm).
Electromedia® I Operating Characteristics
  • Filter Rate: Up to 18 gpm per sq. ft.
  • Backwash Rate: 20 gpm per sq. ft.
  • Required Backwash Time: 4 minutes maximum.
  • Clean Filter Differential Pressure: 1 psi.
  • Terminal Differential Pressure: 10 psi.
Standard Equipment
  • Flow range from 10 to 10,500 gpm or more.
  • 60 psi pressure tank ASME code, stamped.
  • Filter tanks are carbon steel, epoxy lines at all wetted surfaces.
  • Backwash flow controls, air release valves, and automatic filter control valves provided as standard.
  • Standard interior fittings: cast iron, PVC, and stainless steel.
  • Each tank fitted with 12" X16" manholes, 6" x 8" hand holes, or manways depending on filter size.
Automation
  • PLC based automatic filter controls include automatic reset timers for filtration, backwash and purge.
  • Backwash is initiated by time or differential pressure override.
  • Controls housed in a NEMA 12 enclosure.
Tank Sizing Chart

CASE STUDIES:


San Joaquin Valley, CA

Geary, KS

Park City, UT

 
DOWNLOADS:

EM-I Bulletin

General Mineral Analysis

Pilot Test Bulletin

EM-IX Arsenic/Fluoride Treatment

 
 
Electromedia® I Filtration System
 

Electromedia® Case Studies

Electromedia® Installations

   
(Return to the previous page)
Treatment Solutions for:

© Electromedia® is a registered trademark of Filtronics, Incorporated. Copyright 1992,2008 by Filtronics, Incorporated.